Physical features of electric-welding intestinal anastomosis

Authors

  • S. S. Podpriatov Clinical research centre of bonding/welding surgery and new surgical technologies, Kyiv, Ukraine Kyiv City Clinical No. 1, Ukraine Shupyk National Medical Academy of Postgraduate Education, Kyiv, Ukraine, Ukraine https://orcid.org/0000-0001-5942-6311
  • S. E. Podpryatov Clinical research centre of bonding/welding surgery and new surgical technologies, Kyiv, Ukraine Kyiv City Clinical No. 1, Ukraine Paton Electric Welding Institute of National Academy of Sciences of Ukraine, Kyiv, Ukraine
  • S. G. Gichka Bogomolets National Medical University, Kyiv, Ukraine, Ukraine
  • V. G. Hetman Shupyk National Medical Academy of Postgraduate Education, Kyiv, Ukraine, Ukraine https://orcid.org/0000-0002-8768-5385
  • A. V. Makarov Shupyk National Medical Academy of Postgraduate Education, Kyiv, Ukraine, Ukraine
  • G. S. Marinsky Paton Electric Welding Institute of National Academy of Sciences of Ukraine, Kyiv, Ukraine
  • V. A. Tkachenko Paton Electric Welding Institute of National Academy of Sciences of Ukraine, Kyiv, Ukraine
  • O. V. Chernets Paton Electric Welding Institute of National Academy of Sciences of Ukraine, Kyiv, Ukraine
  • V. A. Vasylchenko Paton Electric Welding Institute of National Academy of Sciences of Ukraine, Kyiv, Ukraine
  • D. V. Tarnavsky National University of Life and Environmental Sciences of Ukraine, Kyiv, Ukraine

DOI:

https://doi.org/10.15574/PS.2018.61.69

Keywords:

intestine, anastomosis, bursting pressure, elasticity, leakage, swine, experiment

Abstract

Several researchers believe that the modulus of elasticity (Young’s) more accurately reflects the mechanical tissue properties and intestinal anastomosis healing rather than bursting pressure, which is a consistent parameter. These measures are not widely used until establishing the structural strength, up to 7-14 days, but electric-welding anastomosis line is characterized by primary structural unity.

Objective: to study the bursting strength and circular anastomosis elasticity, created by high-frequency live tissue welding (HF LTW), and to compare them with clinical requirements.

Material and methods. Under the conditions of an acute experiment, anastomoses measuring 25 mm in diameter created on the swine small intestine were investigated: 16 electro-welded, 4 stapled and 4 single-row sutured ones. The gut segment, 20 cm in length, was slowly filled by coloured NaCl solution up to tightness loss. Anastomosis diameter change was determined simultaneously by its projection on the measuring ruler.

Results. Tissue cutting by staples was noted at a pressure of 24.2±0.8 mm Hg, diameter change of 12%, and Young’s modulus – 384 Pa. The mucosal eversion and start of suture cutting were noted at a pressure of 41.3±5.1 mm Hg, diameter change of 20%, and elasticity – 1093 Pa. The welding line leakage occurred after prolonged uniform stretching, at 53.6±9.8 mm Hg. The diameter change was 40% and elastic constant – 2880 Pa.

Conclusions. The combination of high elasticity and structural homogeneity of electro-welded anastomosis stretching is a relatively more reliable mechanism for avoiding early leakage. The obtained data determine the welding line propulsion involvement resulted in early stool appearance, as well as its resistance to sudden intra-abdominal pressure changes. The latter is an advantage for early patient activation, paediatric surgery and frequently fluid stool cases.

References

Nureyev VN, Leont'yev VM, Vorotnikov AM, Tatarinskiy MV, Revin AN. (1988). Rentgeno-radionuklidnyy metod diagnostiki rannikh oslozhneniy posle operatsii na tolstoy kishke (In Russian). X-ray radionuclide method for early after colon surgery complications diagnosing. Aktual'nyye voprosy spetsializirovannoy meditsinskoy pomoshchi. Moscow: Voyennoye izdatel'stvo: 217–219.

Paton BE, Ivanova OM. (Editors). (2009). Tkanesokhraniayushchaya vysokochastotnaya elektrosvarochnaya khirurgiya (in Russian). The live tissue preserving high-frequency electric welding surgery. Athlas. Kyiv: Naukova Dumka: 193.

Beard JD, Nicholson ML, Sayers RD, Lloyd D, Everson NW. (1990, Oct). Intraoperative air testing of colorectal anastomoses: a prospective, randomized trial. Br J Surg. 77(10): 1095–1097. https://doi.org/10.1002/bjs.1800771006

Bosmans JWAM, Jongen ACHM, Bouvy ND, Derikx JPM. (2015). Colorectal anastomotic healing: why the biological processes that lead to anastomotic leakage should be revealed prior to conducting intervention studies. BMC Gastroenterology. 15: 180. https://doi.org/10.1186/s12876-015-0410-3.

Christensen H, Langfelt S, Laurberg S. (1993). Bursting Strength of Experimental Colonic Anastomoses. A Methodological Study. Eur Surg Res. 25: 38–45. https://doi.org/10.1159/000129255; PMid:8482304

Hendriks T, Mastboom WJB. (1990). Healing of experimental intestinal anastomoses. Parameters for repair. Review. Dis Colon Rectum. 33(10): 891–901. https://doi.org/10.1007/BF02051930; PMid:2209281

Iwanaga TC, Aguiar JL de A, Martins-Filho ED, Kreimer F, Silva–Filho FL, de Albuquerque AV. (2016). Analysis of biomechanical parameters in colonic anastomosis. Arquivos Brasileiros de Cirurgia Digestiva: ABCD. 29(2): 90–92. https://doi.org/10.1590/0102-6720201600020006.

Issue